Corrugated Culvert
Roladuct galvanised culvert pipe is manufactured in a range of sizes from 203mm diameter to 3000mm and in lengths to suit your individual needs. The 4 ply lockseam adds strength and rigidity to a versatile pipe with many uses on the farm or in mining and general industrial applications.
Manufactured in accordance with AS 2041.4:2010.
This table summarises the calculations and gives data equivalent to those in Table 3.3 S75 of Australian Standard 2041.4:2010.
Corrugations 75mm x 25mm deep
Material Thickness Sine Profile: | 1.6 | 2.0 | 3.0 |
---|---|---|---|
Section Area mm²/mm: | 1.98 | 2.48 | 3.73 |
Second Moment of Area mm4/mm: | 149.13 | 187.27 | 284.15 |
Section Modulus mm³/mm: | 11.05 | 13.67 | 20.01 |
Radius of Gyration mm: | 8.67 | 8.69 | 8.73 |
Preferred Diameters and Thickness
Metric mm | Thickness mm | Area m² | Mass kg/m | Min Cover mm |
---|---|---|---|---|
203 | 1.6 | 0.031 | 10 | 600 |
305 | 1.6 | 0.072 | 15 | 600 |
381 | 1.6 | 0.112 | 19 | 600 |
457 | 1.6 | 0.161 | 23 | 600 |
610 | 1.6 | 0.290 | 30 | 600 |
762 | 1.6 | 0.452 | 38 | 600 |
914 | 1.6 | 0.652 | 45 | 600 |
1069 | 1.6 | 0.893 | 53 | 600 |
1219 | 1.6 | 1.161 | 60 | 600 |
1524 | 1.6 | 1.817 | 76 | 600 |
1829 | 1.6 | 2.619 | 92 | 600 |
2133 | 2.0 | 3.561 | 140 | 600 |
2438 | 2.0 | 4.655 | 160 | 600 |
3000 | 3.0 | - | 300 | 600 |
Installation Procedure
Culvert should be laid on a firm, well compacted granular bed 100mm deep in a trench 500mm wider than the pipe diameter. Back fill with well compacted selected material passing 75mm screen in 150mm deep layers. Continue restricted back fill until minimum cover then bulk earthwork to final level.
Back Fill
External Joiner
Fittings as Required
- 2 Piece 45°
- 2 Piece 90°
- Tee
- Cross
- 45° Lateral
- Y Piece